    16 Zone Conventional, Control Panels , Large System, EN54 Systems, it's a Fire Alarm System having 16 conventional Zone circuits (expandable to 28) and 4 conventional Sounder circuits Microprocessor based design. Robust metal enclosure c/w lift off lid & heavy-duty base connections. 16 conventional Zone circuits (expandable to 28). 4 conventional Sounder circuits. Separate indicators for open circuit, short circuit, head-out, sounder & battery/power supply faults. Non-latching class change sounder input, latching fire & non-latching fault outputs (via expansion loom). Zone selectable short circuit=fire facility (pre-1980 BS, no resistors in call points). Up to 8 two-wire Repeaters per Main panel. Multi-lingual variants (subject to quantities). Space for 2 x 12V 7Ah VRLA batteries. Compatible with virtually all known conventional fire detectors including C-TEC’s ActiV range. Designed to comply with BS 5839-4 (this panel in not compliant with EN54-2/4 and should NOT be used in new UK or European installations). Follow Us on Facebook Contact Us

  • February 1, 2024

    FX201 CONVENTIONAL CALL POINT is a Fire Alarm System UK its length/depth is 87 mm and its width is 87 mm. product branding is Eaton the color is red CATALOG NUMBER: FX201 EAN: 5021621252079 PRODUCT LENGTH/DEPTH: 87 mm PRODUCT HEIGHT: 53 mm PRODUCT WIDTH: 87 mm PRODUCT WEIGHT: 0.2 kg Follow Us on Facebook Contact Us

  • February 18, 2024

    IFP-2100 HV Fire Alarm Control System having Operating Temperature: 32°F to 120°F (0°C to 49°C) and 18AH max. allowed in control panel PHYSICAL Overall Dimensions: 26.4”H x 16.4"W x 4.11”D Shipping Weight: 33 lbs. Color: Red or Black ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 0 to 93% relative humidity (noncondensing) ELECTRICAL IFP-2100 Primary AC: 120VAC @ 50/60Hz, 4.5A IFP-2100HV AC: 240VAC @ 50/60Hz, 2.8A Total Accessory Load: 9A @ 24VDC power-limited Standby Current: 230mA Alarm Current: 415mA Battery Charging Capacity: 17 to 55AH Battery Size: 18AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Six Conductor Wiring: Two voice bus & four SBUS   Follow Us on Facebook Contact Us

  • February 18, 2024

    Signaling Line Circuit Expander 6815 The 6815 is a signaling line circuit (SLC) expander for use, Silent Knight 6820 or 6820EVS fire alarm control panels (FACPs)using Silent Knight 6820 or 6820EVS fire alarm control panels (FACPs)using System Sensor® (SK) protocol. The 6815 signaling circuit has the same functionality as the SLC that is built into the 6820 and 6820EVS panels and support the same addressable devices as the one in each panel. The number of 6815 SLCs that can be used within one system is largely dependent on maximum available points. They provide a powerful way to customize configurations in large or complex installs.   Follow Us on Facebook Contact Us

  • February 18, 2024

    IDP-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The IDP-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector’s address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the IDP-PHOTO-T. The IDP-PHOTO-R is a remote test capable detector for use with DNR Series duct detector housings. Weight 1 lbs Dimensions 5 × 5 × 5 in Color Ivory Device Addressing Rotary Dials Sensing Element Photoelectric Series Farenhyt IDP-PHOTO-W Series: Intelligent Plug-in Photoelectric Smoke Detectors, Farenhyt Series System Type Addressable   Follow Us on [...]

  • February 18, 2024

    The IDP-Heat, IDP-Heat-HT and IDP-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector’s address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Heat-ROR is a fixed temperature and rate-of-rise thermal detector that uses a thermistor sensing circuit to produce 135°F (57°C) thermal protection. Weight 1 lbs Dimensions 5 × 5 × 5 in Color Ivory Construction Polymer Device Addressing Rotary Dials Heat Sensing Element Fixed Temperature, Rate-of-Rise Thermal Rating 135°F System Type Addressable Follow Us on Facebook Contact Us