{"id":3353,"date":"2024-02-18T07:51:43","date_gmt":"2024-02-18T07:51:43","guid":{"rendered":"https:\/\/www.kyrcompany.com\/?p=3353"},"modified":"2024-03-19T09:37:31","modified_gmt":"2024-03-19T09:37:31","slug":"efbwcv-repeater-fire-alarm","status":"publish","type":"post","link":"https:\/\/www.kyrcompany.com\/kdc\/efbwcv-repeater-fire-alarm","title":{"rendered":"EFBWCV-REPEATER ( Fire Alarm )"},"content":{"rendered":"<p>EFBWCV-REPEATER BiWire and Conventional repeater panel is a Fire Alarm System compatible with our 2 zone, 4 zone and 8 zone BiWire-Ultra (EFBWxZONE), BiWire-Flexi (EFBWxZFLEXI) and the latest release of conventional panels (EFCVxZ).<\/p>\n<p>Up to 3 EFBWCV repeater panels can be daisy-chained to a single control panel, allowing all repeater panels to replicate the visual and audible fire and fault information of the control panel.<\/p>\n<p>With an integral power supply the only wiring required for the repeater panel is the mains input to the power supply unit and the data cable between the fire control panel and each repeater panel.<\/p>\n<h3>Features<\/h3>\n<p>\u2022 Can be used with 2, 4 and 8 zone control panels<br \/>\n\u2022 Internal Power supply<br \/>\n\u2022 Up to 3 repeaters per control panel<br \/>\n\u2022 Same modern enclosure as control panels Benefits<br \/>\n\u2022 One model fits 2, 4 and 8 zone control panel installations<br \/>\n\u2022 Simple unit cabling<br \/>\n\u2022 Ability to have several repeaters on same installation<br \/>\n\u2022 Family look<br \/>\n\u2022 Repeater panel not out of place in public areas<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-3355\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27303%27%20height%3D%27264%27%20viewBox%3D%270%200%20303%20264%27%3E%3Crect%20width%3D%27303%27%20height%3D%27264%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.kyrcompany.com\/wp-content\/uploads\/2024\/02\/4155237-40.jpg\" alt=\"EFBWCV-REPEATER BiWire Conventional repeater Fire Alarm System EFBWxZONE \" width=\"303\" height=\"264\" \/><br \/>\n1. When the fire panel enters a fault condition it will turn on the General Fault indicator and the appropriate fault indicator (refer to 8 for more details). The repeater will display the same General Fault and appropriate fault indicators.<\/p>\n<p>2. System Fault \u2013 Severe failure of the panel, the service company must be contacted immediately. Repeater Fault \u2013 Communication between a detection and a repeater panel has been lost<\/p>\n<p>3. Battery Fault \u2013 Battery voltage missing Mains Fault \u2013 Mains supply missing<br \/>\n4. Battery Failure \u2013 Battery impedance failure Charger Fault \u2013 Charger voltage missing<br \/>\n5. Sounder Fault \u2013 Short circuit or open circuit condition detected on the sounder circuit will prevent the activation of sounders if fitted on that sounder circuit<br \/>\n6. FRE Fault \u2013 Short circuit or open circuit condition detected on the FRE output<br \/>\n7. FPE Fault \u2013 Short circuit or open circuit condition detected on the FPE output<br \/>\n8. Zone Fault \u2013 Short circuit or open circuit condition detected on the zone.<\/p>\n<div>\n<div><a href=\"https:\/\/www.linkedin.com\/in\/kyr-for-supplying-and-installing-equipment-8a69b4277\">Follow Us on Linkedin<\/a><\/div>\n<div><a href=\"https:\/\/www.kyrcompany.com\/contact-us\/\">Contact Us<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>EFBWCV-REPEATER BiWire and Conventional repeater panel is a Fire Alarm System compatible with our 2 zone, 4 zone and 8 zone BiWire-Ultra (EFBWxZONE), BiWire-Flexi (EFBWxZFLEXI) and the latest release of conventional panels (EFCVxZ). Up to 3 EFBWCV repeater panels can be daisy-chained to a single control panel, allowing all repeater panels to replicate the visual and audible fire and fault information of the control panel. With an integral power supply the only wiring required for the repeater panel is the [&#8230;]<\/p>\n","protected":false},"author":1,"featured_media":3465,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"EFBWCV-REPEATER BiWire and Conventional repeater panel is a Fire Alarm System compatible with our 2 zone, 4 zone and 8 zone BiWire-Ultra (EFBWxZONE)","_seopress_robots_index":"","footnotes":""},"categories":[2],"tags":[],"class_list":["post-3353","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fire-alarm-system"],"_links":{"self":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts\/3353","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/comments?post=3353"}],"version-history":[{"count":1,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts\/3353\/revisions"}],"predecessor-version":[{"id":3466,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts\/3353\/revisions\/3466"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/media\/3465"}],"wp:attachment":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/media?parent=3353"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/categories?post=3353"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/tags?post=3353"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}