{"id":3295,"date":"2024-02-15T13:38:36","date_gmt":"2024-02-15T13:38:36","guid":{"rendered":"https:\/\/www.kyrcompany.com\/?p=3295"},"modified":"2024-03-19T10:31:19","modified_gmt":"2024-03-19T10:31:19","slug":"ulmiu872-ul-micro-zone-monitor-unit","status":"publish","type":"post","link":"https:\/\/www.kyrcompany.com\/kdc\/ulmiu872-ul-micro-zone-monitor-unit","title":{"rendered":"ULMIU872-UL micro zone monitor unit"},"content":{"rendered":"<p>ULMIU872-UL micro zone monitor unit is an extremely compact unit ideal for incorporation in external equipment, it is a single zone input unit, soft addressed<br \/>\nand incorporates integral short circuit isolators.<\/p>\n<p>It is suitable for interfacing a zone of up to 20 Eaton UL conventional detectors onto a Eaton UL intelligent addressable control panel. It will operate with any Eaton UL conventional detector in configuration with the UL conventional base (CB2E).<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-3296\" src=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27256%27%20height%3D%27256%27%20viewBox%3D%270%200%20256%20256%27%3E%3Crect%20width%3D%27256%27%20height%3D%27256%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-orig-src=\"https:\/\/www.kyrcompany.com\/wp-content\/uploads\/2024\/02\/fire-ul-zone-unit-module.jpg\" alt=\"ULMIU872-UL micro zone monitor unit single zone input\" width=\"256\" height=\"256\" \/><\/p>\n<h3>Features and benefits<\/h3>\n<p>\u2022 Soft addressed<br \/>\n\u2022 Integral short circuit isolator<br \/>\n\u2022 Single address<br \/>\n\u2022 Accepts a zone of Eaton UL conventional detectors<br \/>\n\u2022 Input monitored for open and short ground trouble<br \/>\n\u2022 Quick and simple to install<br \/>\n\u2022 No hard addressing required (plug and play)<br \/>\n\u2022 Compact size<br \/>\n\u2022 Easy to expand a system using existing wiring<\/p>\n<h3>Installation<\/h3>\n<p>1. Fit the unit in position in accordance to the mounting details.<br \/>\n2. Connect the unit according to standard connections.<br \/>\n3. Up to 3 units can be fitted inside a micro module box unit.<\/p>\n<h3>Operation<\/h3>\n<p>Normal standby \/ alarm \/ alarm test \/alarm Silence \/ alarm reset \/ trouble \/trouble silence \/ Off normal position of switches<\/p>\n<div><a href=\"https:\/\/www.linkedin.com\/in\/kyr-for-supplying-and-installing-equipment-8a69b4277\">Follow Us on Linkedin<\/a><\/div>\n<div><a href=\"https:\/\/www.kyrcompany.com\/contact-us\/\">Contact Us<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>ULMIU872-UL micro zone monitor unit is an extremely compact unit ideal for incorporation in external equipment, it is a single zone input unit, soft addressed and incorporates integral short circuit isolators. It is suitable for interfacing a zone of up to 20 Eaton UL conventional detectors onto a Eaton UL intelligent addressable control panel. It will operate with any Eaton UL conventional detector in configuration with the UL conventional base (CB2E). Features and benefits \u2022 Soft addressed \u2022 Integral short [&#8230;]<\/p>\n","protected":false},"author":1,"featured_media":3489,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"ULMIU872-UL micro zone monitor unit is an extremely compact unit ideal for incorporation in external equipment, it is a single zone input unit, soft addressed","_seopress_robots_index":"","footnotes":""},"categories":[2],"tags":[],"class_list":["post-3295","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-fire-alarm-system"],"_links":{"self":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts\/3295","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/comments?post=3295"}],"version-history":[{"count":2,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts\/3295\/revisions"}],"predecessor-version":[{"id":3579,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/posts\/3295\/revisions\/3579"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/media\/3489"}],"wp:attachment":[{"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/media?parent=3295"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/categories?post=3295"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/kdc\/wp-json\/wp\/v2\/tags?post=3295"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}