{"id":3140,"date":"2024-02-14T11:38:56","date_gmt":"2024-02-14T11:38:56","guid":{"rendered":"https:\/\/www.kyrcompany.com\/ar\/?p=3140"},"modified":"2024-03-19T12:41:52","modified_gmt":"2024-03-19T12:41:52","slug":"the-isolator-intercall-nurse-call","status":"publish","type":"post","link":"https:\/\/www.kyrcompany.com\/ar\/the-isolator-intercall-nurse-call","title":{"rendered":"\u0639\u0627\u0632\u0644 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a"},"content":{"rendered":"<p>\u0639\u0627\u0632\u0644 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0647\u0648 \u0646\u0638\u0627\u0645 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0628\u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a \u0647\u0648 \u0627\u0641\u0636\u0644 \u0648\u0633\u064a\u0644\u0629 \u0644\u0631\u0641\u0639 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062e\u062f\u0645\u0629 \u0641\u0649 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a \u062d\u064a\u062b \u064a\u0642\u0648\u0645 \u0627\u0644\u0646\u0638\u0627\u0645 \u0628\u0625\u0638\u0647\u0627\u0631 \u0631\u0642\u0645 \u0627\u0644\u063a\u0631\u0641\u0629 \u0623\u0648 \u0627\u0644\u0633\u0631\u064a\u0631 \u0639\u0644\u0649 \u0644\u0648\u062d\u0629 \u0627\u0644\u0628\u064a\u0627\u0646<\/p>\n<p>The Isolator is an Intercall Nurse call which used to protect the output from the Controller and limits the current available to the radials and Devices. The Bus cable connects to the Input and provides four current limited outputs for connection the the Radial cables and on to the Devices. There is a through terminal which allows the Bus cable to continue to the next Isolator as required.<\/p>\n<h3>Input Terminals<\/h3>\n<p>There are two sets of green terminals which accept the Bus cable from the Controller and allow it to pass through onto the next Isolator as required. The terminals are linked together within the Isolator.<\/p>\n<h3>Output Terminals<\/h3>\n<p>There are 4 sets of output terminals to connect the Radial cables to the Devices. The connectors may be unplugged without removing the cables simplifying fault finding. Caution: Observe Polarity when making these connections !<\/p>\n<h3>Output Protection Fuses<\/h3>\n<p>Each output is current limited with an individual fuse. Fuse Rating: 1 Amp Anti- Surge\/Slow Blow.<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-3141\" src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992.png\" data-orig-src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992.png\" alt=\"\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0639\u0627\u0632\u0644 \u0644\u0631\u0641\u0639 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062e\u062f\u0645\u0629 \u0644\u0648\u062d\u0629 \u0627\u0644\u0628\u064a\u0627\u0646 \" width=\"309\" height=\"309\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27309%27%20height%3D%27309%27%20viewBox%3D%270%200%20309%20309%27%3E%3Crect%20width%3D%27309%27%20height%3D%27309%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-66x66.png 66w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-150x150.png 150w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-200x200.png 200w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-300x300.png 300w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-400x400.png 400w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-600x600.png 600w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992-768x768.png 768w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/101_isolator__33992.png 800w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 309px) 100vw, 309px\" \/><\/p>\n<h2>Installation<\/h2>\n<h3>Front Panel LEDs<\/h3>\n<p>The front Panel LEDs indicate Green for Bus Heath and Red for a fault on the individual outputs.<\/p>\n<h3>Installation<\/h3>\n<p>Flush or surface mount into standard &#8216;double sized&#8217; electrical back box provided by others or ordered separately.<\/p>\n<h3>3.10.6 Size and Weight<\/h3>\n<p>The unit is supplied as a flush mounted plate. Size: W148mm x H88mm x D35mm Weight: 110g. Required Backbox: Double Gang minimum depth 25mm<\/p>\n<div><a href=\"https:\/\/www.linkedin.com\/in\/kyr-for-supplying-and-installing-equipment-8a69b4277\">Follow Us on Linkedin<\/a><\/div>\n<div><a href=\"https:\/\/www.kyrcompany.com\/ar\/contact-us\/\">Contact Us<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u0639\u0627\u0632\u0644 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0647\u0648 \u0646\u0638\u0627\u0645 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0628\u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a \u0647\u0648 \u0627\u0641\u0636\u0644 \u0648\u0633\u064a\u0644\u0629 \u0644\u0631\u0641\u0639 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062e\u062f\u0645\u0629 \u0641\u0649 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a \u062d\u064a\u062b \u064a\u0642\u0648\u0645 \u0627\u0644\u0646\u0638\u0627\u0645 \u0628\u0625\u0638\u0647\u0627\u0631 \u0631\u0642\u0645 \u0627\u0644\u063a\u0631\u0641\u0629 \u0623\u0648 \u0627\u0644\u0633\u0631\u064a\u0631 \u0639\u0644\u0649 \u0644\u0648\u062d\u0629 \u0627\u0644\u0628\u064a\u0627\u0646 The Isolator is an Intercall Nurse call which used to protect the output from the Controller and limits the current available to the radials and Devices. The Bus cable connects to the Input and provides four current limited outputs for connection the the Radial cables and on to the Devices. There is [&#8230;]<\/p>\n","protected":false},"author":2,"featured_media":3141,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"%%post_title%% %%sep%% %%sitetitle%%","_seopress_titles_desc":"\u0639\u0627\u0632\u0644 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0647\u0648 \u0646\u0638\u0627\u0645 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0628\u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a \u0647\u0648 \u0627\u0641\u0636\u0644 \u0648\u0633\u064a\u0644\u0629 \u0644\u0631\u0641\u0639 \u0643\u0641\u0627\u0621\u0629 \u0627\u0644\u062e\u062f\u0645\u0629 \u0641\u0649 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u064a\u0627\u062a \u062d\u064a\u062b \u064a\u0642\u0648\u0645 \u0627\u0644\u0646\u0638\u0627\u0645 \u0628\u0625\u0638\u0647\u0627\u0631 \u0631\u0642\u0645 \u0627\u0644\u063a\u0631\u0641\u0629 \u0639\u0644\u0649 \u0644\u0648\u062d\u0629 \u0627\u0644\u0628\u064a\u0627\u0646","_seopress_robots_index":"","footnotes":""},"categories":[44],"tags":[],"class_list":["post-3140","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-intercall-nurse-call"],"_links":{"self":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3140","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/comments?post=3140"}],"version-history":[{"count":4,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3140\/revisions"}],"predecessor-version":[{"id":4030,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3140\/revisions\/4030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media\/3141"}],"wp:attachment":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media?parent=3140"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/categories?post=3140"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/tags?post=3140"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}