{"id":3106,"date":"2024-02-14T08:29:58","date_gmt":"2024-02-14T08:29:58","guid":{"rendered":"https:\/\/www.kyrcompany.com\/ar\/?p=3106"},"modified":"2024-03-19T12:44:54","modified_gmt":"2024-03-19T12:44:54","slug":"l622-standard-call-point-intercall","status":"publish","type":"post","link":"https:\/\/www.kyrcompany.com\/ar\/l622-standard-call-point-intercall","title":{"rendered":"L622 \u0648\u062d\u062f\u0629 \u0646\u062f\u0627\u0621 \u0641\u0631\u0639\u064a\u0629 (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621)"},"content":{"rendered":"<p>L622 \u0648\u062d\u062f\u0629 \u0646\u062f\u0627\u0621 \u0641\u0631\u0639\u064a\u0629 (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621) \u062a\u0645 \u062a\u0635\u0645\u064a\u0645 \u0646\u0638\u0627\u0645\u00a0 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0644\u062a\u0648\u0641\u064a\u0631 \u0645\u0631\u0648\u0646\u0629 \u062a\u0627\u0645\u0629 \u0641\u064a \u0627\u0644\u062a\u0643\u0648\u064a\u0646\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647 \u0627\u0644\u062d\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u064a \u0645\u0647\u0645\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \u0644\u0644\u0645\u0646\u0632\u0644 \u0623\u0648 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u0649.<\/p>\n<p>The L622 is an Intercall Nurse call the standard call point for the Intercall 600 non audio system and can generate up to six independent call levels indicated by the twin colour re-assurance LED. The \u2018call follower\u2019 sounder which is activated when the call point is in \u2018staff present\u2019 mode, alerts staff to other calls on the system. The jack socket will accept any closing contact input from pear leads, pressure mats, radio triggers and a host of other triggering devices.<\/p>\n<p>The X, X2 and L terminals are<br \/>\nused to connect to CS1 Ceiling Pull Switches or SCP Slave Call Points. The L2 &amp; X3 terminals are for SRP Slave Call Point connections. A Magnetic Reset version is available, order code L622M. For Non-Latching and remote reset applications, please see the L634 on page 37.<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-3107\" src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914.jpg\" data-orig-src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914.jpg\" alt=\"\u0648\u062d\u062f\u0629 \u0646\u062f\u0627\u0621 \u0641\u0631\u0639\u064a\u0629 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 L622 \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \" width=\"282\" height=\"282\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27282%27%20height%3D%27282%27%20viewBox%3D%270%200%20282%20282%27%3E%3Crect%20width%3D%27282%27%20height%3D%27282%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-66x66.jpg 66w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-150x150.jpg 150w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-200x200.jpg 200w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-300x300.jpg 300w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-400x400.jpg 400w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-600x600.jpg 600w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914-768x768.jpg 768w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L622_front__29914.jpg 800w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 282px) 100vw, 282px\" \/><\/p>\n<h3>Network Terminals:<\/h3>\n<p>Connect to the Intercall 600 (2 wire) Network. [+, \u2013] OBSERVE POLARITY<\/p>\n<h3>X Terminal:<\/h3>\n<p>Standard Call Input which automatically generates System Text 3.<br \/>\nThis allows the input to have a secondary description, for example \u2018Ensuite\u2019<\/p>\n<h3>X2 Terminal:<\/h3>\n<p>Emergency Call Input which automatically generates System Text 4.<br \/>\nThis allows the input to have a secondary description, for example \u2018Bathroom\u2019<\/p>\n<h3>X3 Terminal:<\/h3>\n<p>Reset \/ Present Input for SRP Slave Reset Points<\/p>\n<h3>Re-assurance LED:<\/h3>\n<p>Slow Red flashing \u2013 Standard Call<br \/>\nSlow Red\/Green flashing \u2013 Assistance Call<br \/>\nRapid Red flashing \u2013 Emergency\/Crash Call<br \/>\nGreen flashing &#8211; Accepted Call \u2013 Staff on their way<br \/>\nConstant Green \u2013 Nurse Present Mode<\/p>\n<h3>L Terminal:<\/h3>\n<p>Red LED Output for ceiling pull switches with built in re-assurance lights.<br \/>\nL2 Terminal: Green LED Output for SRP (Slave Reset Points).<\/p>\n<h3>Pear lead Socket:<\/h3>\n<p>Industry standard socket that will accept any normally open switch.<br \/>\nThis socket can accept input from pear leads, pressure mats, radio triggers etc.<\/p>\n<h3>uInstallation:<\/h3>\n<p>Flush or surface mount in standard \u2018single size\u2019 electrical backbox.<\/p>\n<h3>Size &amp; Weights:<\/h3>\n<p>80 x 80 x 40 mm, 70g<\/p>\n<div><a href=\"https:\/\/www.linkedin.com\/in\/kyr-for-supplying-and-installing-equipment-8a69b4277\">Follow Us on Linkedin<\/a><\/div>\n<div><a href=\"https:\/\/www.kyrcompany.com\/ar\/contact-us\/\">Contact Us<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>L622 \u0648\u062d\u062f\u0629 \u0646\u062f\u0627\u0621 \u0641\u0631\u0639\u064a\u0629 (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621) \u062a\u0645 \u062a\u0635\u0645\u064a\u0645 \u0646\u0638\u0627\u0645\u00a0 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0644\u062a\u0648\u0641\u064a\u0631 \u0645\u0631\u0648\u0646\u0629 \u062a\u0627\u0645\u0629 \u0641\u064a \u0627\u0644\u062a\u0643\u0648\u064a\u0646\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647 \u0627\u0644\u062d\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u064a \u0645\u0647\u0645\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \u0644\u0644\u0645\u0646\u0632\u0644 \u0623\u0648 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u0649. The L622 is an Intercall Nurse call the standard call point for the Intercall 600 non audio system and can generate up to six independent call levels indicated by the twin colour re-assurance LED. The \u2018call follower\u2019 sounder which is activated when the call point is in \u2018staff present\u2019 mode, alerts staff to [&#8230;]<\/p>\n","protected":false},"author":2,"featured_media":3107,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"%%post_title%% %%sep%% %%sitetitle%%","_seopress_titles_desc":"L622 \u0648\u062d\u062f\u0629 \u0646\u062f\u0627\u0621 \u0641\u0631\u0639\u064a\u0629 (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621) \u062a\u0645 \u062a\u0635\u0645\u064a\u0645 \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0644\u062a\u0648\u0641\u064a\u0631 \u0645\u0631\u0648\u0646\u0629 \u062a\u0627\u0645\u0629 \u0641\u064a \u0627\u0644\u062a\u0643\u0648\u064a\u0646\u060c \u0645\u0645\u0627 \u064a\u062c\u0639\u0644\u0647 \u0627\u0644\u062d\u0644 \u0627\u0644\u0645\u062b\u0627\u0644\u064a \u0645\u0647\u0645\u0627 \u0643\u0627\u0646\u062a \u0627\u0644\u0645\u062a\u0637\u0644\u0628\u0627\u062a \u0627\u0644\u0641\u0631\u062f\u064a\u0629 \u0644\u0644\u0645\u0646\u0632\u0644 \u0623\u0648 \u0627\u0644\u0645\u0633\u062a\u0634\u0641\u0649.&nbsp;","_seopress_robots_index":"","footnotes":""},"categories":[44],"tags":[],"class_list":["post-3106","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-intercall-nurse-call"],"_links":{"self":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3106","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/comments?post=3106"}],"version-history":[{"count":5,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3106\/revisions"}],"predecessor-version":[{"id":3697,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3106\/revisions\/3697"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media\/3107"}],"wp:attachment":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media?parent=3106"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/categories?post=3106"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/tags?post=3106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}