{"id":3095,"date":"2024-02-14T07:58:32","date_gmt":"2024-02-14T07:58:32","guid":{"rendered":"https:\/\/www.kyrcompany.com\/ar\/?p=3095"},"modified":"2024-03-19T12:46:04","modified_gmt":"2024-03-19T12:46:04","slug":"l628-lcd-display-unit-intercall","status":"publish","type":"post","link":"https:\/\/www.kyrcompany.com\/ar\/l628-lcd-display-unit-intercall","title":{"rendered":"L628 LCD \u0645\u062d\u0637\u0629 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621)"},"content":{"rendered":"<p>L628 LCD \u0645\u062d\u0637\u0629 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621) \u0645\u0635\u0645\u0645\u0629 \u0644\u0625\u0639\u0637\u0627\u0621 \u0625\u0634\u0627\u0631\u0629 \u0648\u0627\u0636\u062d\u0629 \u0648\u0625\u0646\u0630\u0627\u0631 \u0641\u064a \u0643\u0644 \u0645\u0648\u0642\u0639 \u0645\u0631\u0627\u0642\u0628\u0629. \u0648\u062a\u062a\u0645\u064a\u0632 \u0627\u0644\u0648\u062d\u062f\u0629 \u0628\u0634\u0627\u0634\u0629 LCD \u0645\u0639 \u0625\u0636\u0627\u0621\u0629 \u062e\u0644\u0641\u064a\u0629<\/p>\n<h1>L628 LCD Display Unit<\/h1>\n<p>L628 LCD Display Unit is an Intercall Nurse call. A display unit is required in every location where calls are to be shown and the alarm is to sound. The L628 features two-line LCD display with backlight and a multi-level adjustable alarm. (See page 5 for more information) It is capable of sounding a different tone for selected call points (doors, drug cupboards, telephone, etc) and only displaying specific call points (Zoning) if required.<\/p>\n<p>More information can be found from page 51. There is an open collector output, which can be connected to the RB1 Relay Board [See Page 32] or used to directly trigger external equipment. All displays are identical but can be configured on site to operate independently.<\/p>\n<h3>Network Terminals:<\/h3>\n<p>Connect to the Intercall 600 (2 wire) Network. [+, \u2013] OBSERVE POLARITY<\/p>\n<h3>Z0, Z1, Z2:<\/h3>\n<p>Connect to zone switch or wire link (See \u2018Zone Switch Connection\u2019 Below)<\/p>\n<h3>OC Output Terminal:<\/h3>\n<p>Open collector output active continuously when the alarm is sounding.<br \/>\nNote: Rating 12vDC 100mA. Minimum [ON] resistance = 100 Ohms.<br \/>\nThe OC terminal may be used to trigger an external device directly, which will accept this<br \/>\ntype of input. Alternatively you may connect this terminal to a RB1 Relay Board which will<br \/>\nprovide normally open &amp; normally closed \u2018dry\u2019 contacts.<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-3096\" src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit.jpg\" data-orig-src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit.jpg\" alt=\"\u0645\u062d\u0637\u0629 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a \u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621 \u0625\u0634\u0627\u0631\u0629 \u0648\u0627\u0636\u062d\u0629 \u0648\u0625\u0646\u0630\u0627\u0631 L628 LCD \" width=\"402\" height=\"402\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27402%27%20height%3D%27402%27%20viewBox%3D%270%200%20402%20402%27%3E%3Crect%20width%3D%27402%27%20height%3D%27402%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit-66x66.jpg 66w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit-150x150.jpg 150w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit-200x200.jpg 200w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit-300x300.jpg 300w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit-400x400.jpg 400w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/02\/L628-LCD-Display-Unit.jpg 576w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 402px) 100vw, 402px\" \/><\/p>\n<h3>Night Alarm Setting:<\/h3>\n<p>This controls the alarm volume when in \u2018night\u2019 mode.<\/p>\n<h3>Day Alarm Setting:<\/h3>\n<p>This controls the alarm volume when in \u2018day\u2019 mode.<br \/>\nTo change between the \u2018day\u2019 and \u2018night\u2019 mode you will need to connect a switch to the<br \/>\nDAY\/NIGHT terminals on the Master Power supply.<\/p>\n<h3>Menu Enable Jumper:<\/h3>\n<p>Remove to prevent access to the engineers display menu.<\/p>\n<h3>Sounder output:<\/h3>\n<p>Typical Maximum 92db@30cm.<\/p>\n<h3>Zone Switch:<\/h3>\n<p>This text is intended as a technical reference only and details of zoning are discussed on<br \/>\npage 54. When a display is required to only sound for specific call points, we need to<br \/>\nconnect a switch or permanent wire link to the \u2018Z\u2019 terminals. The following connections<br \/>\nforce the display to use the address windows that are programmed on site:<br \/>\nZ1 Not Connected, &amp; Z2 Not Connected = Global (Sound for all calls)<br \/>\nZ1 Not Connected &amp; Z2 Connected to Z0 = Use Address Window C<br \/>\nZ1 Connected to Z0 &amp; Z2 Not Connected = Use Address Window B<br \/>\nZ1 Connected to Z0 &amp; Z2 Connected to Z0 = Use Address Window A<\/p>\n<h3>Installation:<\/h3>\n<p>Flush mount &#8211; use standard \u2018double size\u2019 electrical backbox. Surface mount use BB1 (See<br \/>\npage 16). Connects to system two core and optional zone switch and auxiliary devices.<\/p>\n<h3>Size &amp; Weights:<\/h3>\n<p>80 x 140 x 40 mm, 200g<\/p>\n<div><a href=\"https:\/\/www.linkedin.com\/in\/kyr-for-supplying-and-installing-equipment-8a69b4277\">Follow Us on Linkedin<\/a><\/div>\n<div><a href=\"https:\/\/www.kyrcompany.com\/ar\/contact-us\/\">Contact Us<\/a><\/div>\n","protected":false},"excerpt":{"rendered":"<p>L628 LCD \u0645\u062d\u0637\u0629 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621) \u0645\u0635\u0645\u0645\u0629 \u0644\u0625\u0639\u0637\u0627\u0621 \u0625\u0634\u0627\u0631\u0629 \u0648\u0627\u0636\u062d\u0629 \u0648\u0625\u0646\u0630\u0627\u0631 \u0641\u064a \u0643\u0644 \u0645\u0648\u0642\u0639 \u0645\u0631\u0627\u0642\u0628\u0629. \u0648\u062a\u062a\u0645\u064a\u0632 \u0627\u0644\u0648\u062d\u062f\u0629 \u0628\u0634\u0627\u0634\u0629 LCD \u0645\u0639 \u0625\u0636\u0627\u0621\u0629 \u062e\u0644\u0641\u064a\u0629 L628 LCD Display Unit L628 LCD Display Unit is an Intercall Nurse call. A display unit is required in every location where calls are to be shown and the alarm is to sound. The L628 features two-line LCD display with backlight and a multi-level adjustable alarm. (See page 5 for more information) It is capable of sounding [&#8230;]<\/p>\n","protected":false},"author":2,"featured_media":3096,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"%%post_title%% %%sep%% %%sitetitle%%","_seopress_titles_desc":"L628 LCD \u0645\u062d\u0637\u0629 \u0627\u0633\u062a\u062f\u0639\u0627\u0621 \u0627\u0644\u0645\u0645\u0631\u0636\u0627\u062a (\u0646\u0638\u0627\u0645 \u0646\u062f\u0627\u0621) \u0645\u0635\u0645\u0645\u0629 \u0644\u0625\u0639\u0637\u0627\u0621 \u0625\u0634\u0627\u0631\u0629 \u0648\u0627\u0636\u062d\u0629 \u0648\u0625\u0646\u0630\u0627\u0631 \u0641\u064a \u0643\u0644 \u0645\u0648\u0642\u0639 \u0645\u0631\u0627\u0642\u0628\u0629. \u0648\u062a\u062a\u0645\u064a\u0632 \u0627\u0644\u0648\u062d\u062f\u0629 \u0628\u0634\u0627\u0634\u0629 LCD \u0645\u0639 \u0625\u0636\u0627\u0621\u0629 \u062e\u0644\u0641\u064a\u0629","_seopress_robots_index":"","footnotes":""},"categories":[44],"tags":[],"class_list":["post-3095","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-intercall-nurse-call"],"_links":{"self":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3095","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/comments?post=3095"}],"version-history":[{"count":5,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3095\/revisions"}],"predecessor-version":[{"id":4039,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/3095\/revisions\/4039"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media\/3096"}],"wp:attachment":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media?parent=3095"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/categories?post=3095"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/tags?post=3095"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}