{"id":2523,"date":"2024-01-31T11:50:55","date_gmt":"2024-01-31T11:50:55","guid":{"rendered":"https:\/\/www.kyrcompany.com\/ar\/?p=2523"},"modified":"2024-03-19T13:01:57","modified_gmt":"2024-03-19T13:01:57","slug":"mxa1060-integrated-mixing-amplifier","status":"publish","type":"post","link":"https:\/\/www.kyrcompany.com\/ar\/mxa1060-integrated-mixing-amplifier","title":{"rendered":"MXA1060 \u0648\u062d\u062f\u0629 \u062a\u0643\u0628\u064a\u0631 \u0627\u0644\u0635\u0648\u062a"},"content":{"rendered":"<p>MXA1060 \u0648\u062d\u062f\u0629 \u062a\u0643\u0628\u064a\u0631 \u0627\u0644\u0635\u0648\u062a\u00a0\u0633\u064a\u0648\u0641\u0631 \u0627\u0644\u0645\u0635\u0647\u0631 \u0627\u0644\u0645\u062f\u0645\u062c \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0627\u0644\u064a\u0629 \u0644\u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a. \u0648\u064a\u0645\u0643\u0646\u0647 \u0627\u0643\u062a\u0634\u0627\u0641 \u0623\u062e\u0637\u0627\u0621 \u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u062a\u0644\u0642\u0627\u0626\u064a\u064b\u0627 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644.<\/p>\n<p>Integrated mixing amplifier MXA1060 it&#8217;s a sound system having 2 microphone inputs with phantom power supply (XLR). MIC 1 with automatic precedence\u00a0function (VOX) and threshold adjustment control<\/p>\n<p>PRODUCT DESCRIPTION<br \/>\n2 microphone inputs with phantom power supply (XLR). MIC 1 with automatic precedence\u00a0function (VOX) and threshold adjustment control<br \/>\nMicrophone input (XLR) with phantom power supply or RJ45 for connecting up to 6 MBT 1101 microphone stations (maximum distance 200 m)<br \/>\nMIC\/PH\/LINE input with associated selector switch 2 auxiliary inputs for sound sources (TAPE\/CD)<br \/>\nTelephone\/emergency audio input for priority calls with adjustable threshold and sensitivity<br \/>\nFront-panel level control for each microphone and auxiliary input<\/p>\n<p><img decoding=\"async\" class=\"lazyload alignnone wp-image-2524 size-medium\" src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875-300x225.jpg\" data-orig-src=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875-300x225.jpg\" alt=\"MXA1060 \u0648\u062d\u062f\u0629 \u062a\u0643\u0628\u064a\u0631 \u0627\u0644\u0635\u0648\u062a \u0627\u0644\u0645\u0635\u0647\u0631 \u0627\u0644\u0645\u062f\u0645\u062c \" width=\"300\" height=\"225\" srcset=\"data:image\/svg+xml,%3Csvg%20xmlns%3D%27http%3A%2F%2Fwww.w3.org%2F2000%2Fsvg%27%20width%3D%27300%27%20height%3D%27225%27%20viewBox%3D%270%200%20300%20225%27%3E%3Crect%20width%3D%27300%27%20height%3D%27225%27%20fill-opacity%3D%220%22%2F%3E%3C%2Fsvg%3E\" data-srcset=\"https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875-200x150.jpg 200w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875-300x225.jpg 300w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875-400x300.jpg 400w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875-600x450.jpg 600w, https:\/\/www.kyrcompany.com\/ar\/wp-content\/uploads\/sites\/3\/2024\/01\/fbt-mxa-1060-intergrated-amplifier_0_18c0dd1875.jpg 650w\" data-sizes=\"auto\" data-orig-sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Front panel overall volume control and treble and bass controls<br \/>\nConstant voltage (50\/70\/100 V) or 8 impedance loudspeaker line output<br \/>\nAuxiliary line output<br \/>\nLED-type Vu meter for immediate monitoring of output power<br \/>\nMicro switches for setting priorities and input functions<br \/>\nInclusion\/exclusion of speech filter on all microphone inputs<br \/>\nContacts for activating input precedence<br \/>\nAlerting signal (chime) with level control<br \/>\nSelectable 230\/115 VAC and 24 VDC mains power supply<\/p>\n<div><\/div>\n<div>\n<div><a href=\"https:\/\/www.linkedin.com\/in\/kyr-for-supplying-and-installing-equipment-8a69b4277\">Follow Us on Linkedin<\/a><\/div>\n<div><a href=\"https:\/\/www.kyrcompany.com\/ar\/contact-us\/\">Contact Us<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>MXA1060 \u0648\u062d\u062f\u0629 \u062a\u0643\u0628\u064a\u0631 \u0627\u0644\u0635\u0648\u062a\u00a0\u0633\u064a\u0648\u0641\u0631 \u0627\u0644\u0645\u0635\u0647\u0631 \u0627\u0644\u0645\u062f\u0645\u062c \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0627\u0644\u064a\u0629 \u0644\u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a. \u0648\u064a\u0645\u0643\u0646\u0647 \u0627\u0643\u062a\u0634\u0627\u0641 \u0623\u062e\u0637\u0627\u0621 \u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u062a\u0644\u0642\u0627\u0626\u064a\u064b\u0627 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644. Integrated mixing amplifier MXA1060 it&#8217;s a sound system having 2 microphone inputs with phantom power supply (XLR). MIC 1 with automatic precedence\u00a0function (VOX) and threshold adjustment control PRODUCT DESCRIPTION 2 microphone inputs with phantom power supply (XLR). MIC 1 with automatic precedence\u00a0function (VOX) and threshold adjustment control Microphone input (XLR) with phantom power supply or RJ45 for connecting up to 6 [&#8230;]<\/p>\n","protected":false},"author":2,"featured_media":2524,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"%%post_title%% %%sep%% %%sitetitle%%","_seopress_titles_desc":"MXA1060 \u0648\u062d\u062f\u0629 \u062a\u0643\u0628\u064a\u0631 \u0627\u0644\u0635\u0648\u062a \u0633\u064a\u0648\u0641\u0631 \u0627\u0644\u0645\u0635\u0647\u0631 \u0627\u0644\u0645\u062f\u0645\u062c \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062d\u0627\u0644\u064a\u0629 \u0644\u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0631\u0626\u064a\u0633\u064a. \u0648\u064a\u0645\u0643\u0646\u0647 \u0627\u0643\u062a\u0634\u0627\u0641 \u0623\u062e\u0637\u0627\u0621 \u0645\u0635\u062f\u0631 \u0627\u0644\u0637\u0627\u0642\u0629 \u062a\u0644\u0642\u0627\u0626\u064a\u064b\u0627 \u0623\u062b\u0646\u0627\u0621 \u0627\u0644\u062a\u0634\u063a\u064a\u0644.","_seopress_robots_index":"","footnotes":""},"categories":[73],"tags":[],"class_list":["post-2523","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-amplifiers"],"_links":{"self":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/2523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/comments?post=2523"}],"version-history":[{"count":5,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/2523\/revisions"}],"predecessor-version":[{"id":4095,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/posts\/2523\/revisions\/4095"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media\/2524"}],"wp:attachment":[{"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/media?parent=2523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/categories?post=2523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kyrcompany.com\/ar\/wp-json\/wp\/v2\/tags?post=2523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}